    Summary

    Constant call tone, or odd buzzing on KB-3MRD master station.

    Solution

    Shorted wires on CN-12 can cause this issue to occur. Make sure unused wires on CN-12 are isolated (cut and insulate if necessary).

    Constant Call Tone on KB-3MRD No Audio Through Handset While Using KB-3MRD/HRD No Call Tone or Chime When A Door Station Calls KB-3MRD or KB-3HRD
    • ringtone
    • notification

    Was this article helpful?

    Give feedback about this article

    Recently viewed

    IXG Support Tool 6.0.0.3 (Released 04/08/2025)
    IX Series Support Tool Ver. 11.0.0.2 (Released 10/1/2024)
    NHX-80X Technical Specifications
    IX-1AS/IX-10AS Technical Specifications
    AXW-PA1 Technical Specifications

    Related articles

    No Call Tone or Chime When A Door Station Calls KB-3MRD or KB-3HRD
    Eliminating Call Tone from Sub Station at LEF Master Station
    Adding an IS-SOFT Client to an Existing System

    Articles in this section

    Constant Call Tone on KB-3MRD
    No Audio Through Handset While Using KB-3MRD/HRD
    No Call Tone or Chime When A Door Station Calls KB-3MRD or KB-3HRD

    Welcome to Aiphone's Technical Knowledge Base

    Home Contact Us What's New in AiphoneCloud Where to Buy Aiphone
    Legal & Policies

    ©2026 Aiphone. All Rights reserved.

    Knowledge Base Software powered by Helpjuice