Occasionally, when attempting to upload or download settings from IX/IXG stations, an E_001 failure message may be encountered. This code indicates a communication issue between the stations and support tool, caused by outdated firmware.
If this happens, it needs to be corrected by installing the IX | IXG Support Tool additional authentication data patch and updating firmware on the affected stations.
Installing the IX | IXG Support Tool additional authentication data patch:
- Click the link in the E_001 popup.
- When prompted, enter the station type and corresponding MAC address.
- Download the patch and follow the prompts to install it..
Updating station firmware:
- Download the latest firmware from Know.aiphone.com.
- Update the firmware using the IXG Support Tool or web interface.
After making these fixes, be sure to upload settings to the stations to confirm the issue was resolved.